Repairing a Marstek Venus E 3.0

Recently I got a damaged Marstek Venus E 3.0 home battery. The battery was damaged during transport and reported 0% capacity. I decided to open it and see if I could repair it.

The good news: the battery is now working again. But I was quite surprised by how difficult Marstek has made it to repair this device.

Opening the Marstek

The first problem is opening the case. The front plexiglass panel is glued to the housing. Behind this panel are the screws needed to remove the cover.

In my case, the transport damage had already broken several screws so the front panel came off easily. Normally, removing it without damaging the panel seems almost impossible.

Once the cover is removed, the battery cells and inverter electronics become visible.

Inside the Marstek Venus E 3.0.

And this is where the next surprise comes.

Almost all the electronics are covered in a thick sticky black silicone-like compound. It is impossible to inspect or replace most individual components.

The inverter electronics covered in black compound.

It makes repairing the electronics difficult. Combined with the glued front panel, it almost looks as if Marstek doesn’t want anyone to repair these devices.

Finding the Problem

The cells are connected using aluminium busbars. These also have spot-welded connections to a PCB which the BMS (Battery Management System) uses to measure the individual cell voltages.

Three of these connections had broken loose.

One of the damaged BMS connections.

The main busbars still appeared to be properly connected to the cells. Only the smaller BMS sensing connections had come loose. This explains why the battery reported 0% capacity.

I repaired it using a short wire soldered to the original sensing contact on the PCB. The other end was connected to the busbar using a crimped ring terminal secured with a bolt.

The case of the battery was damaged in one corner, but there is some space between the outer case and the cells. This seems to have protected the cells from the impact. I could not find any physical damage to the cells themselves.

Testing the Repaired Battery

After repairing the connections, the battery showed a State of Charge again. To make sure everything was working correctly, I fully charged and discharged the battery several times.

During these tests I monitored the battery temperatures and individual cell voltages. I did not notice any abnormal temperatures, unusual voltage differences or other problems.

As far as I can determine, the battery is now fully functional again.

All 16 cells are well balanced. Lowest cell 3.334 V, cell 11. Highest cell 3.340 V, cells 8 & 14. Voltage difference: 6 mV

Marstek Diagnostics: API, Modbus and Bluetooth

There are several ways to get detailed information from the device without relying on the official app.

I found three useful methods:

1. Local API (UDP port 30000)

Marstek has a local API that can be used to retrieve battery information and control certain functions. This can also be used for home automation.

More information is available in the official Marstek API documentation.

2. Modbus TCP (port 502)

Modbus provides more detailed information, including the individual cell voltages, temperatures and other BMS data.

On my Venus E 3.0, Modbus TCP only works over the wired Ethernet connection, not Wi-Fi.

The Marstek Venus Modbus project on GitHub contains useful information about the registers.

The port on the right is the ethernet port.

3. Bluetooth (BLE)

There are also some interesting community-developed tools that connect directly to the Marstek using Bluetooth.

These work in a Chrome browser using Web Bluetooth. No additional software is needed.

For example, Marstek BLE Control can read detailed device information, change settings and even perform firmware updates.

Another useful project is Marstek Venus Monitor.

Firmware Update to Version 151

My Marstek was running an older EMS firmware version 135. I was unable to update to a newer version via the Marstek iOS app.

But using the Bluetooth tool, I successfully updated it to version 151 – There is a Marstek firmware archive on GitHub containing firmware files and version information for different Marstek models.

Conclusion

Repairing this Marstek turned out to be successful. The actual problem was relatively simple: three broken BMS sensing connections caused by transport damage.

After repairing them and running several full charge and discharge cycles, the battery appears to work completely normally.

Leave a Reply